Carbon monoxide, venting and the safety checks a buyer should ask for

Going deeper · 1 study hours

Bottom line: Carbon monoxide comes from fuel burned without enough air or vented badly; the EPA lists leaking chimneys and furnaces, blocked or disconnected flues and attached-garage exhaust among the sources, and says to have a trained professional inspect, clean and tune up the heating system every year. This lesson turns that into the exact checks a buyer writes into an inspection request, and what each costs on our example house.

Health facts and source lists below are quoted from the EPA carbon monoxide page named in the cites, as it read when checked. Alarm rules are from C.R.S. 38-45-101 and 38-45-102. Every price is a made-up example.

Bottom line first. A furnace can run, heat the house and still poison the people in it. Carbon monoxide is the gas you cannot see or smell that forms when fuel burns without enough air or when the exhaust does not make it outside. The EPA's own list of indoor sources includes "leaking chimneys and furnaces," "automobile exhaust from attached garages," and "worn or poorly adjusted and maintained combustion devices (e.g., boilers, furnaces) if the flue is improperly sized, blocked or disconnected" (cite: EPA CO page). A buyer cannot see any of those from the living room. This lesson gives you the five checks to ask for, in the words an inspector and an HVAC contractor understand.

How the exhaust is supposed to leave

The flue (also called the vent) is the pipe that carries combustion gases from a furnace or water heater to the outdoors. In an older furnace like the 1996 unit on our example house, hot exhaust rises on its own; that natural rising pull is called draft. A metal flue that leaks at a joint, slopes the wrong way or dumps into a crumbling chimney loses its draft and leaks gas into the house. A newer condensing furnace (the 90-plus AFUE type) does not rely on rising heat at all; a fan pushes cool exhaust out through plastic pipe, and a second pipe often brings in combustion air, the fresh air the burner needs. That sealed design is one reason high-efficiency furnaces are also usually safer furnaces.

Two failure words to know. Backdrafting is when exhaust reverses and flows back down the flue into the room, often because a bath fan, dryer or range hood is pulling air out of a tight house faster than it can get back in. Spillage is the milder version: exhaust that rolls out around the draft hood (the open metal collar on top of an older furnace or water heater) for the first minute or two before the flue warms up. A little spillage at start-up is normal on old equipment; spillage that never stops is not.

Why the numbers on the EPA page matter to a buyer

The EPA describes typical indoor levels in parts per million (ppm), which just means how many molecules of CO are in a million molecules of air. It states: "Average levels in homes without gas stoves vary from 0.5 to 5 parts per million (ppm). Levels near properly adjusted gas stoves are often 5 to 15 ppm and those near poorly adjusted stoves may be 30 ppm or higher" (cite: EPA CO page). The symptoms it lists at low levels are fatigue in healthy people and chest pain in people with heart disease; at higher levels, "impaired vision and coordination; headaches; dizziness; confusion; nausea," and it notes CO "can cause flu-like symptoms that clear up after leaving home" (cite: EPA CO page). That last phrase is the buyer's clue when talking to a seller or a tenant: a house where people feel better at work than at home deserves a combustion test before anything else.

The EPA's prevention list is short and it is the heart of this lesson: "Have a trained professional inspect, clean and tune-up central heating system (furnaces, flues and chimneys) annually. Repair any leaks promptly," plus "Do not idle the car inside garage" and "Keep gas appliances properly adjusted" (cite: EPA CO page). The page also passes along the Consumer Product Safety Commission's advice that every home have CO alarms "on each level outside each sleeping area" (cite: EPA CO page). Colorado law is narrower, so do both: meet the statute, then follow the CPSC placement.

The five checks to write into an inspection request

  1. Combustion analysis. A combustion analyzer is a hand-held meter with a probe the technician puts into the flue to read CO, oxygen and temperature in the exhaust. Ask for the printed readout, not a verbal "it's fine." A general home inspector usually does not carry one; an HVAC contractor does.
  2. Heat exchanger inspection. Lesson 2 covered the cracked exchanger. Ask for a camera or visual inspection with the blower door off, and ask whether the burner flames stay steady and blue when the blower starts. Flames that lift or roll when the fan kicks on are a classic sign that air is leaking across a crack.
  3. Vent inspection. Every joint screwed, sloping upward toward the chimney, no rust holes, no gaps where the water heater and furnace vents join, and a proper flue liner (a metal or clay pipe inside a masonry chimney that keeps gases from soaking into the brick). If the house has a condensing furnace, check that the plastic vent ends outdoors with the right clearance from windows and that the intake is not next to a dryer vent.
  4. Draft and spillage test. With every exhaust fan in the house running and the doors closed, does the water heater or furnace still draft? A smoke pencil or a mirror at the draft hood answers this in a minute.
  5. Alarm placement. Under C.R.S. 38-45-102, a seller of an existing single-family house that "has a fuel-fired heater or appliance, a fireplace, or an attached garage" must assure an operational CO alarm "within fifteen feet of the entrance to each room lawfully used for sleeping purposes" when the house is offered for sale or transfer on or after July 1, 2009 (cite: C.R.S. 38-45-102). "Operational" means "working and in service in accordance with manufacturer instructions" (cite: C.R.S. 38-45-101). Count sleeping rooms, measure, and ask for what is missing.

One more item that is not required by any Colorado statute but that many HVAC technicians recommend: a low-level CO monitor, a plug-in meter that shows a running ppm number and sounds at concentrations far below the point where a standard alarm reacts. Standard alarms are built to warn of life-threatening levels; a low-level monitor tells you a flue is starting to fail weeks earlier.

Example with real numbers

Juniper Loop, Longmont, the 1996 two-story. Dana and Marcus have the inspection report from Lesson 2: gas furnace (80 AFUE, metal flue into a masonry chimney), gas water heater sharing that chimney, wood fireplace, attached garage, four bedrooms with one in the basement. Before closing, Dana writes a repair-and-inspection request with made-up example prices:

  • Combustion analysis plus heat exchanger inspection by a licensed HVAC contractor: example $190. Result: exchanger sound (the Lesson 3 story), CO in the flue reads an example 38 ppm at steady state, which the technician calls acceptable for an old burner but worth watching. Room air by the furnace reads 0 to 1 ppm, inside the EPA's 0.5 to 5 ppm range for homes without gas stoves (cite: EPA CO page).
  • Vent inspection: the shared flue has one unscrewed joint and a short section sloping downhill where someone moved the water heater. Example repair: $240 to re-pitch and screw the vent connector. The chimney has a clay liner with no visible breaks; a chimney sweep's camera scan is quoted at an example $175 and Dana adds it.
  • Draft test with fans running: the water heater spills for about 90 seconds at start-up, then drafts. The technician notes the basement is tight and recommends a louvered door to the furnace room for combustion air. Example cost: $120 for the door, installed by the handyman already coming for other items.
  • Alarm placement: upstairs hallway alarm covers the three upstairs bedrooms (9 feet and 14 feet, all within fifteen feet). The basement bedroom has none, so the seller must supply one before transfer under the statute (cite: C.R.S. 38-45-102). Example $35. Dana also asks for a second alarm on the main floor near the garage door, following the CPSC each-level advice (cite: EPA CO page); example $35, which she pays herself since the law does not require it.

Total example cost of making the house safe to live in this winter: $190 + $240 + $175 + $120 + $35 + $35 = $795. The seller agrees to the $35 basement alarm and the $240 vent repair in the inspection resolution; Dana and Marcus pay the rest, about $520. Compare that to the $6,800 to $16,900 replacement bids from Lesson 3: this is the small money that buys the first safe season while they decide the big question in Lesson 7.

What a buyer should carry away: the furnace replacement decision is about money and comfort; the venting and alarm checks are about whether anyone gets hurt before that decision is made. Do the safety list first, every time, and keep the printed combustion readout with the house papers so the next technician has a baseline.

Law cited

Key terms

Flue (vent)
The pipe that carries combustion gases from a furnace or water heater to the outdoors.
Draft
The natural upward pull of hot exhaust through a flue; lost when a flue leaks, slopes down or is blocked.
Combustion air
The fresh air a burner needs; sealed condensing furnaces bring it in through a dedicated pipe.
Backdrafting
Exhaust reversing and flowing back into the house, often because fans pull air out faster than it returns.
Spillage
Exhaust rolling out around the draft hood before the flue warms up; brief at start-up is normal, continuous is not.
Draft hood
The open metal collar on top of an older furnace or water heater where the flue starts.
Parts per million (ppm)
A concentration unit: how many CO molecules per million molecules of air.
Combustion analyzer
A hand-held meter with a flue probe that reads CO, oxygen and exhaust temperature.
Flue liner
A metal or clay pipe inside a masonry chimney that keeps gases from soaking into the brick.
Low-level CO monitor
A plug-in meter showing a running ppm reading that warns well below standard-alarm levels; recommended, not required by Colorado law.

Flashcards

Three CO sources the EPA names that relate to a house's heating system

Leaking chimneys and furnaces; blocked or disconnected flues on worn or poorly adjusted furnaces; automobile exhaust from attached garages (EPA CO page).

EPA's typical CO level in homes without gas stoves

0.5 to 5 ppm (EPA CO page).

EPA: level near a poorly adjusted gas stove

May be 30 ppm or higher (EPA CO page).

EPA's heating-system prevention advice

Have a trained professional inspect, clean and tune up the central heating system (furnaces, flues and chimneys) annually; repair leaks promptly.

Symptom pattern that points to CO at home

Flu-like symptoms that clear up after leaving home (EPA CO page).

Backdrafting vs spillage

Backdrafting: exhaust reverses into the house. Spillage: brief roll-out at the draft hood before the flue warms.

Colorado alarm distance rule

An operational CO alarm within fifteen feet of the entrance to each room lawfully used for sleeping (C.R.S. 38-45-102).

What makes 'operational' under C.R.S. 38-45-101

Working and in service in accordance with manufacturer instructions.

CPSC placement advice passed along by EPA

CO alarms on each level outside each sleeping area.

The five buyer checks

Combustion analysis, heat exchanger inspection, vent inspection, draft and spillage test, alarm placement.

Quiz: 10 questions

Tap an answer. It shows right or wrong and opens the reason. Your score is saved in this browser and counts in the study app.

  1. Which of these does the EPA page list as an indoor source of carbon monoxide?

    1. A Electric baseboard heaters
    2. B Sealed LED light fixtures
    3. C Leaking chimneys and furnaces
    4. D Ceiling fans
    Show answer and why

    Answer: C. Leaking chimneys and furnaces

    The EPA page names leaking chimneys and furnaces among indoor CO sources.

    EPA: Carbon monoxide's impact on indoor air quality

  2. According to the EPA page, average CO levels in homes without gas stoves are about:

    1. A 0.5 to 5 ppm
    2. B 30 to 50 ppm
    3. C 100 to 200 ppm
    4. D Zero in every home
    Show answer and why

    Answer: A. 0.5 to 5 ppm

    The page states 0.5 to 5 parts per million for homes without gas stoves.

    EPA: Carbon monoxide's impact on indoor air quality

  3. The EPA says CO levels near a poorly adjusted gas stove may be:

    1. A Under 1 ppm
    2. B Exactly 5 ppm
    3. C Always below 15 ppm
    4. D 30 ppm or higher
    Show answer and why

    Answer: D. 30 ppm or higher

    The page says poorly adjusted stoves may produce 30 ppm or higher.

    EPA: Carbon monoxide's impact on indoor air quality

  4. How often does the EPA page say a trained professional should inspect, clean and tune up the central heating system?

    1. A Every five years
    2. B Annually
    3. C Only when it fails
    4. D Only at sale
    Show answer and why

    Answer: B. Annually

    The page says to have the central heating system inspected, cleaned and tuned up annually.

    EPA: Carbon monoxide's impact on indoor air quality

  5. Which symptom pattern does the EPA page tie to carbon monoxide at home?

    1. A Flu-like symptoms that clear up after leaving home
    2. B A rash that appears outdoors
    3. C Symptoms that worsen at work
    4. D Sneezing only in spring
    Show answer and why

    Answer: A. Flu-like symptoms that clear up after leaving home

    The page says CO can cause flu-like symptoms that clear up after leaving home.

    EPA: Carbon monoxide's impact on indoor air quality

  6. Spillage, in this lesson, means:

    1. A Refrigerant leaking from a coil
    2. B Water dripping from a condensate drain
    3. C Exhaust rolling out around the draft hood before the flue warms up
    4. D Gas escaping a loose pipe fitting
    Show answer and why

    Answer: C. Exhaust rolling out around the draft hood before the flue warms up

    Spillage is combustion gas escaping at the draft hood, usually briefly at start-up.

    Lesson definition

  7. Under C.R.S. 38-45-102, an operational CO alarm must be installed within what distance of each sleeping-room entrance?

    1. A Five feet
    2. B Fifteen feet
    3. C Twenty-five feet
    4. D Fifty feet
    Show answer and why

    Answer: B. Fifteen feet

    The statute says within fifteen feet of the entrance to each room lawfully used for sleeping purposes.

    C.R.S. 38-45-102

  8. Which feature does NOT by itself bring a single-family house under C.R.S. 38-45-102?

    1. A A fuel-fired heater or appliance
    2. B A fireplace
    3. C An attached garage
    4. D A detached workshop
    Show answer and why

    Answer: D. A detached workshop

    The statute names a fuel-fired heater or appliance, a fireplace, or an attached garage; a detached building is not on the list.

    C.R.S. 38-45-102

  9. Under C.R.S. 38-45-101, 'operational' means the alarm is:

    1. A Working and in service in accordance with manufacturer instructions
    2. B Less than ten years old
    3. C Hard-wired to house power
    4. D Approved by the county
    Show answer and why

    Answer: A. Working and in service in accordance with manufacturer instructions

    The definition is working and in service in accordance with manufacturer instructions.

    C.R.S. 38-45-101

  10. The CPSC advice the EPA page passes along is to put CO alarms:

    1. A Only in the furnace room
    2. B Only in the kitchen
    3. C On each level outside each sleeping area
    4. D Only in the attached garage
    Show answer and why

    Answer: C. On each level outside each sleeping area

    The page quotes CPSC: CO alarms on each level outside each sleeping area.

    EPA: Carbon monoxide's impact on indoor air quality