Refrigerant changes and hiring the contractor: permits, load calculations and bids
Refrigerants and hiring the installer · 1 study hours
Bottom line: The AIM Act is phasing down HFC refrigerants; EPA says any new split system installed after January 1, 2026 must use a refrigerant with a GWP under 700, while existing R-410A systems can still be repaired, and the right installer pulls a permit, runs a Manual J load calculation and writes an itemized bid.
Dates and rules on refrigerants below are quoted from the EPA page named in the cites, as it read when checked. Example prices are made up.
Bottom line first. The refrigerant inside air conditioners and heat pumps is changing by law, which affects what you can buy and what repairs cost. The EPA states: "Any new split system installed after January 1, 2026, must use refrigerant with a GWP less than 700. The GWP limits do not apply to systems installed before January 1, 2026" (cite: EPA HFC phasedown FAQ). And on repairs: "Homeowners can maintain and repair their systems throughout the useful life of the equipment" (cite: EPA HFC phasedown FAQ). So you are not forced to replace a working unit, but a new system today uses a newer refrigerant, and the installer you choose matters more than the brand.
Refrigerants in plain words
HFCs (hydrofluorocarbons) are the family of refrigerants that replaced the older ozone-depleting ones. The EPA describes them as potent greenhouse gases, with climate impacts "hundreds to thousands of times greater than the same amount of carbon dioxide" (cite: EPA HFC phasedown FAQ). GWP, global warming potential, is the measure: a gas with a GWP of 700 warms 700 times more than the same weight of carbon dioxide, which has a GWP of 1 (cite: EPA HFC phasedown FAQ).
The AIM Act (American Innovation and Manufacturing Act), enacted December 27, 2020, requires HFCs to be phased down 85 percent from baseline by 2036 (cite: EPA HFC phasedown FAQ). EPA runs that in three ways: limiting how much HFC can be made or imported each year (allowances), restricting which refrigerants new equipment can use (the Technology Transitions program), and rules on reclaiming and not venting refrigerant (cite: EPA HFC phasedown FAQ).
What that means at your house:
- R-22: the old refrigerant in units like the 2004 AC on our example house. It was phased out earlier under ozone rules; supply is reclaimed stock only, so a recharge is expensive and the unit is a replace candidate the moment it leaks.
- R-410A: the common refrigerant in systems installed roughly from the mid-2000s through 2025. The EPA says a homeowner "can replace a faulty component (e.g., condensing unit, indoor coil, other smaller parts) with a similar R-410A component," but "After January 1, 2026, if a whole new system is installed it must use lower-GWP refrigerant" (cite: EPA HFC phasedown FAQ). Expect R-410A prices to rise as allowances shrink; repairs stay legal, just dearer.
- Lower-GWP refrigerants (the A2L class, marketed under names like R-454B and R-32): what new systems use. They are mildly flammable, so new equipment carries leak sensors and installers need updated training. This is a reason to pick an installer who has already done many of these installs.
One wrinkle the EPA addressed: for variable refrigerant flow (VRF) systems, EPA's December 12, 2024 rule allows installs with higher-GWP HFCs until January 1, 2027 if the components were manufactured or imported before the deadline (cite: EPA HFC phasedown FAQ). Most houses do not have VRF; it is a commercial and large-home product.
Hiring the contractor
Equipment brands matter far less than installation quality. Judge the installer on four things.
1. Permit. A furnace, AC or heat pump replacement needs a mechanical permit from your city or county building department in most of Colorado, and often an electrical permit for a heat pump. The permit brings an inspector who checks venting, gas connections, clearances, condensate drains and the disconnect. Remember Lesson 2: a permitted fuel-fired appliance replacement in a single-family house triggers the CO alarm rule (cite: C.R.S. 38-45-102). A bidder who offers to skip the permit to save money is offering to skip the inspection that protects you.
2. Manual J load calculation. Manual J is the industry method for calculating how much heating and cooling a specific house needs, using its square footage, insulation, windows, orientation and air leakage. The output is in BTU per hour and sets the size of the equipment. Oversized equipment short cycles and dehumidifies poorly; undersized cannot keep up on the coldest night. A bidder who sizes by "same as the old one" or by square feet alone has not done the work. Ask for the Manual J report with the bid. A sibling method, Manual D, sizes the ducts; ask whether the existing ducts can carry the new airflow.
3. The bid. A good bid is itemized: equipment model numbers (indoor and outdoor), AHRI certificate, AFUE/SEER2/HSPF2, refrigerant type, permit fee, electrical work, duct changes, thermostat, haul-away, warranty terms (parts and labor separately), and every credit or rebate line from Lesson 4. Get three. Compare the same scope.
4. Licensing and insurance. Colorado licenses plumbers and electricians at the state level, while mechanical (HVAC) contractor licensing is handled by cities and counties, so ask the building department what license your installer needs and verify it there. Ask for proof of general liability and workers' compensation insurance.
Example with real numbers
Juniper Loop, Longmont, last visit. Dana and Marcus chose Bidder A's dual-fuel cold-climate heat pump with a 96 AFUE furnace (example net $13,900 from Lesson 4). Before signing, they check the four items.
- Permit: Bidder A's bid lists a mechanical permit and an electrical permit for the new 240-volt circuit to the heat pump. Example line: $310 for both permits. Bidder B's bid had no permit line; when asked, B said "we can pull one if you want, add $350." That answer told Dana what she needed to know.
- Manual J: Bidder A's report shows the 2,100-square-foot house with updated attic insulation needs an example 54,000 BTU per hour of heat on the design cold day and 30,000 BTU per hour of cooling. The old furnace was 100,000 BTU input, nearly double what the house needs, which explains years of short cycling. A proposes an example 3-ton heat pump (36,000 BTU per hour of cooling) and a 60,000 BTU furnace. Smaller, cheaper to run, and right-sized.
- Refrigerant: the new heat pump uses a lower-GWP A2L refrigerant, as any new split system installed after January 1, 2026 must (cite: EPA HFC phasedown FAQ). The bid lists the required leak sensor. The old R-22 unit is recovered and recycled by the installer, as refrigerant rules require; it is never vented.
- CO alarm: because the furnace replacement is permitted work in a house with fuel-fired appliances, the alarm rule applies (cite: C.R.S. 38-45-102). The basement bedroom alarm from Lesson 2 is already in, 11 feet from the door. The inspector checks it at final.
Example timeline: bid signed in March, install in April (off-season), final inspection two weeks later, utility rebate check in June after Dana uploads the AHRI certificate and permit sign-off. Total example out of pocket: $13,900 plus $310 in permits, minus the $1,200 rebate that arrives later, so cash out of about $13,010 at install and $11,810 after the check.
Red flags that end an interview
- "No permit needed" for a furnace or heat pump swap.
- Sizing without a load calculation.
- A bid with one lump-sum number and no model numbers.
- Pressure to sign the same day for a "today only" price.
- Offering to top off an R-22 or R-410A leaker every spring instead of finding the leak.
You now have the whole loop: how the machines work, what the warning signs and the CO law require, the repair-or-replace math, the credits and rebates, and how to buy the install. Run any house through the five lessons and you will know what the furnace means for its price.
Law cited
- EPA: Frequent questions on the phasedown of hydrofluorocarbons (AIM Act)
- C.R.S. 38-45-102
- Worked example with made-up numbers
Key terms
- HFC (hydrofluorocarbon)
- The refrigerant family that replaced ozone-depleting chemicals; potent greenhouse gases now being phased down.
- GWP (global warming potential)
- How much a gas warms the climate compared with the same weight of carbon dioxide, which is 1.
- AIM Act
- The American Innovation and Manufacturing Act of 2020, which requires an 85 percent HFC phasedown by 2036.
- Technology Transitions program
- EPA's rules restricting which refrigerants new equipment may use.
- R-22
- An older refrigerant, phased out under ozone rules; recharge is costly and the unit is a replace candidate.
- R-410A
- The common HFC refrigerant in systems installed roughly 2005 to 2025; repairs allowed, new whole systems after January 1, 2026 may not use it.
- A2L refrigerant
- The mildly flammable, lower-GWP refrigerant class used in new systems, requiring leak sensors and trained installers.
- Split system
- An AC or heat pump with separate indoor and outdoor units connected by refrigerant lines.
- Mechanical permit
- The building-department permit for installing or replacing heating and cooling equipment.
- Manual J
- The industry method for calculating a house's heating and cooling load in BTU per hour to size equipment.
- Manual D
- The companion method for sizing ducts to carry the needed airflow.
- Ton (of cooling)
- 12,000 BTU per hour of cooling capacity; a 3-ton unit is 36,000 BTU per hour.
- Itemized bid
- A bid listing every model number, rating, fee, rebate and warranty term separately.
Flashcards
After what date must a new split system use a refrigerant with GWP under 700?
After January 1, 2026 (EPA HFC phasedown FAQ).
Can you still repair an R-410A system after 2026?
Yes. EPA says homeowners can maintain and repair systems throughout their useful life.
What does GWP 700 mean?
700 times the warming of the same weight of carbon dioxide.
AIM Act phasedown target?
85 percent below baseline by 2036.
When was the AIM Act enacted?
December 27, 2020.
What is Manual J?
The load calculation that sizes heating and cooling equipment for a specific house.
Why is oversized equipment bad?
It short cycles and dehumidifies poorly.
One ton of cooling equals?
12,000 BTU per hour.
Why does a furnace permit matter for CO alarms?
A permitted fuel-fired appliance replacement triggers the alarm rule in C.R.S. 38-45-102.
Biggest red flag in a bid?
No permit, or sizing without a load calculation.
Quiz: 10 questions
Tap an answer. It shows right or wrong and opens the reason. Your score is saved in this browser and counts in the study app.
According to the EPA page, any new split system installed after January 1, 2026 must use a refrigerant with a GWP:
- A Less than 700
- B Less than 7,000
- C Of exactly 1
- D There is no limit
Show answer and why
Answer: A. Less than 700
The EPA page states the under-700 GWP limit for new split systems installed after January 1, 2026.
EPA HFC phasedown FAQ
Your R-410A condensing unit fails in 2027. Per the EPA page, can you replace just that component with a similar R-410A one?
- A No, the whole system must be replaced
- B Yes, homeowners can repair and replace faulty components through the equipment's useful life
- C Only if the house is rented
- D Only with EPA written approval
Show answer and why
Answer: B. Yes, homeowners can repair and replace faulty components through the equipment's useful life
EPA says a homeowner can replace a faulty component with a similar R-410A component; only a whole new system must use lower-GWP refrigerant.
EPA HFC phasedown FAQ
The AIM Act requires HFCs to be phased down by what share, by what year?
- A 50 percent by 2030
- B 100 percent by 2026
- C 85 percent by 2036
- D 15 percent by 2050
Show answer and why
Answer: C. 85 percent by 2036
EPA states an 85 percent phasedown from historic baseline by 2036.
EPA HFC phasedown FAQ
The AIM Act was enacted on:
- A January 1, 2026
- B May 11, 2023
- C December 12, 2024
- D December 27, 2020
Show answer and why
Answer: D. December 27, 2020
EPA gives December 27, 2020 as the enactment date.
EPA HFC phasedown FAQ
A gas with a GWP of 700 has a climate impact per kilogram:
- A 700 times that of carbon dioxide
- B 700 percent less than carbon dioxide
- C Equal to carbon dioxide
- D Measured in BTU
Show answer and why
Answer: A. 700 times that of carbon dioxide
GWP compares a gas with carbon dioxide, which has a GWP of 1.
EPA HFC phasedown FAQ
What is Manual J?
- A A refrigerant recovery method
- B The method for calculating a house's heating and cooling load to size equipment
- C A permit application form
- D A warranty document
Show answer and why
Answer: B. The method for calculating a house's heating and cooling load to size equipment
Manual J produces the BTU-per-hour load used to size the system.
Course lesson
In the Longmont example, the old furnace was 100,000 BTU input and the Manual J heating load is 54,000 BTU per hour. The old unit was:
- A Undersized
- B Correctly sized
- C About the right size for cooling
- D Nearly double what the house needs, which causes short cycling
Show answer and why
Answer: D. Nearly double what the house needs, which causes short cycling
Oversizing leads to short cycling and poor comfort.
Course lesson, example
A 3-ton heat pump delivers how much cooling?
- A 3,000 BTU per hour
- B 12,000 BTU per hour
- C 36,000 BTU per hour
- D 100,000 BTU per hour
Show answer and why
Answer: C. 36,000 BTU per hour
One ton is 12,000 BTU per hour, so three tons is 36,000.
Course lesson
A permitted furnace replacement in a Colorado single-family house with fuel-fired appliances:
- A Needs no inspection
- B Triggers the CO alarm requirement in C.R.S. 38-45-102
- C Voids the equipment warranty
- D Requires a new roof
Show answer and why
Answer: B. Triggers the CO alarm requirement in C.R.S. 38-45-102
The statute lists permitted fuel-fired appliance replacements as a trigger.
C.R.S. 38-45-102
A bidder says the permit is optional and offers to skip it to save money. The course's advice:
- A Take the discount
- B Ask for a bigger discount
- C Treat it as a red flag; the permit brings the inspection that protects you
- D Pull the permit yourself after the work
Show answer and why
Answer: C. Treat it as a red flag; the permit brings the inspection that protects you
Skipping the permit skips the safety inspection.
Course lesson