title: "Replace or repair: comparing bids, efficiency ratings"
description: "Three bids are only comparable once they describe the same scope, the same ratings and the same paperwork."
url: "https://shinnslist.com/courses/furnace-ac-heat-pumps/hvac-07-replace-or-repair-comparing-bids-efficiency-ratings-and"
---

[Furnaces, Air Conditioners and Heat Pumps in Colorado: Free Course](/courses/furnace-ac-heat-pumps/) Light or dark

[Free Courses](/courses/) › [Furnace, AC and heat pump course](/courses/furnace-ac-heat-pumps/) › [Going deeper](/courses/furnace-ac-heat-pumps/#m4) › Lesson 7

# Replace or repair: comparing bids, efficiency ratings and payback on one house

Going deeper · 1 study hours

**Read once:** This course is general education, not legal, tax, engineering or financial advice. Every dollar figure is an example; a real bid, credit or rebate turns on that house, that year's law and your installer.

**Bottom line:** Three bids are only comparable once they describe the same scope, the same ratings and the same paperwork. This lesson lays the example house's bids side by side, converts AFUE, SEER2 and HSPF2 into yearly dollars, adds credits and rebates, and computes simple payback and ten-year cost so the choice is a number, not a feeling.

Credit figures below are quoted from the IRS 25C page and the EPA refrigerant page named in the cites, as they read when checked. Bids, utility costs and savings are made-up examples for one house.

**Bottom line first.** Most owners pick the middle bid because it feels safe. A better way takes twenty minutes: make the bids describe the same job, turn each efficiency rating into dollars per year for your house, subtract the credits and rebates that are real on paper, and divide. Lesson 3 did the first pass on the example house; this lesson is the full comparison a buyer or owner should do before signing.

### Step 1: make the bids match

A **line-item bid** lists each piece of the job with its own price: equipment, labor, permit, electrical, duct changes, haul-away, thermostat. A **lump-sum bid** gives one number. You cannot compare a lump sum to anything, so ask every bidder for line items. Then check the **scope of work**, the written list of what is included, for these items that bidders quietly leave out:

- Permit and inspection. A permitted fuel-fired appliance replacement also triggers the CO alarm requirement in a single-family house (cite: C.R.S. 38-45-102), so the alarm should be in the bid too.

- Electrical work. A heat pump usually needs a new dedicated circuit; a condensing furnace needs a condensate drain and sometimes a pump.

- Duct sealing and a return-air fix. **Static pressure** is the resistance the blower pushes against in the ducts; too high and the new equipment is noisy, short-lived and never reaches its rated efficiency. A good bidder measures it and prices the fix.

- **Commissioning**: the start-up measurements (refrigerant charge, airflow, gas pressure, temperature rise) that prove the system runs as designed. Ask for the sheet.

- Warranty terms. Equipment makers typically cover parts for a set number of years if the unit is registered; labor is the installer's promise and varies widely. Write both down.

- A **matched system**: the outdoor and indoor units tested together as a pair. Lesson 4 explained the AHRI certificate that proves the match; the rating on the certificate is the one credits and rebates use.

### Step 2: turn ratings into dollars

Lesson 1 defined the three ratings. In one line each: **AFUE** is the share of the fuel's heat that reaches the house over a season; **SEER2** is cooling delivered per unit of electricity over a season; **HSPF2** is the same idea for a heat pump's heating. Each is a ratio, so the saving from an upgrade is a percentage of your current bill, and the current bill is the number only you have. Pull twelve months of utility bills, split gas into heating and everything else (the summer gas bill is roughly the everything-else part), and split electricity the same way using spring and fall months as the baseline.

Then the arithmetic. Going from AFUE 80 to AFUE 96 means fuel use for the same heat drops by about 1 minus (80/96), roughly 17 percent. Going from SEER 10 to about 15 SEER2 drops cooling electricity by roughly a third. A heat pump replaces gas heat with electric heat, so you compare the cost of the gas you stop buying with the cost of the electricity you start buying; HSPF2 tells you how many units of heat you get per unit of electricity, and your utility's winter rate turns that into dollars. There is no shortcut around your own bills.

### Step 3: credits, rebates and the refrigerant question

Take only the money that is real on paper. The federal 25C credit on the IRS page is 30 percent of qualified costs with a yearly cap of $2,000 for qualified heat pumps and up to $600 per item for other qualified property such as efficient furnaces and central air conditioners, for property placed in service on or after January 1, 2023 and before December 31, 2025 (cite: IRS 25C page). An install after that window gets nothing under 25C as the page reads today, so a 2026 bid shows $0 on that line unless the law changes. A Colorado heat pump credit discount or a utility rebate counts only if it is written on the bid as a line item (Lesson 4).

Refrigerant matters to the bid date, not just the price. The EPA says any new split system installed after January 1, 2026 must use a refrigerant with a GWP under 700 (cite: EPA HFC phasedown FAQ). A bid for an older R-410A whole system to be installed in 2026 is a bid for equipment that cannot legally go in as a new system; ask the bidder to confirm the refrigerant and the install date in writing.

### Step 4: payback and ten-year cost

**Simple payback** is the net cost divided by the yearly saving, in years. It ignores interest and price changes, which is fine for a first cut. **Ten-year cost** is the net install price plus ten years of estimated energy bills plus expected repairs. Comparing ten-year cost across bids is fairer than payback alone, because payback punishes the option that happens to replace a machine that still works.

A **change order** is a written price change after the contract is signed; a bid that is suspiciously low often grows through change orders for "unforeseen" duct or electrical work. The line-item bid and the static pressure measurement from Step 1 are your defense.

### Example with real numbers

Juniper Loop, Longmont, the 1996 two-story, spring 2026 install. Dana and Marcus have made the three Lesson 3 bids match: each now includes permit, CO alarm, haul-away, a new thermostat, sealing of the basement duct joints and a commissioning sheet. Their bills show an example $1,200 a year of heating gas and $400 a year of cooling electricity.

| Option (example) | Price after rebates | Yearly energy saving | Simple payback | Ten-year cost |
| --- | --- | --- | --- | --- |
| Keep repairing (Lesson 3: $780 now, est. $1,500 more over two winters, then forced replacement) | $2,280 spent, machine still dies | $0 | n/a | $2,280 + $16,000 energy + a replacement anyway |
| Furnace only, 96 AFUE | $6,800 | $190 (gas 80 to 96 AFUE) | 36 years | $6,800 + $14,100 energy = $20,900 |
| Furnace plus 15 SEER2 AC | $12,400, minus an example $400 utility rebate = $12,000 | $190 + $130 = $320 | 38 years | $12,000 + $12,800 energy = $24,800 |
| Dual-fuel cold-climate heat pump plus 96 AFUE furnace | $16,900, minus Colorado credit discount and utility rebate (Lesson 4) = $13,900 | $320 plus an example $240 from running the heat pump instead of gas in mild weather = $560 | 25 years | $13,900 + $10,400 energy = $24,300 |

How the energy column was built: $1,600 a year today, times ten, is $16,000. The furnace-only option saves $190 a year, so ten years is $14,100. Furnace plus AC saves $320 a year, so $12,800. The heat pump option saves $560 a year, so $10,400. All of these are example numbers; the $240 heat pump figure depends entirely on the house's electric rate versus gas rate, which is why Dana asked Bidder A to show that calculation on the bid with their real rates.

What the table says. No option pays back on energy savings alone inside the equipment's life; that is normal for a short-summer Front Range house with cheap gas. The decision is made on ten-year cost and risk. Furnace-only is cheapest over ten years but leaves a 22-year-old R-22 air conditioner that cannot be recharged cheaply (Lesson 5) and will force a second install, a second permit and a second day off work. The two full-replacement options are within $500 of each other over ten years once the heat pump's credit discount and higher saving are in, and the heat pump option is the one that would have earned the larger federal credit in a 2025 install (cite: IRS 25C page), a sign of where policy is pushing. Dana and Marcus choose the dual-fuel heat pump at the example $13,900 net, mostly because its ten-year cost is nearly the same as the furnace-plus-AC bid and it removes the gas burner from service during the long shoulder seasons, which also means less combustion in the house (Lesson 6).

What a buyer should carry away: when you are the buyer rather than the owner, run the same table before you make your offer and ask the seller for the difference between the repair-and-pray path and the cheapest sensible replacement. On this house that is an example $6,800 furnace, and a buyer who asks for a $5,000 credit at closing with this table attached is asking with evidence, not with a feeling.

## Law cited

- IRS: Energy Efficient Home Improvement Credit (section 25C)
- EPA: Frequent questions on the phasedown of hydrofluorocarbons (AIM Act)
- C.R.S. 38-45-102
- Worked example with made-up numbers

## Key terms

Line-item bid A bid listing each part of the job with its own price; the only kind you can compare. Lump-sum bid A single total with no breakdown. Scope of work The written list of everything included in the job. Static pressure The resistance the blower pushes against in the ducts; too high hurts efficiency and equipment life. Commissioning Start-up measurements (charge, airflow, gas pressure, temperature rise) proving the system runs as designed. Matched system Outdoor and indoor units rated together as a pair; the AHRI certificate proves the match. AFUE / SEER2 / HSPF2 Seasonal efficiency ratios for furnace heat, AC cooling and heat pump heating; savings are a percentage of your current bill. Simple payback Net cost divided by yearly saving, in years, ignoring interest. Ten-year cost Net install price plus ten years of estimated energy and repair bills; fairer than payback alone. Change order A written price change after the contract is signed; the way low bids grow.

## Flashcards

### First step before comparing bids

Make them match: line items, same scope (permit, alarm, electrical, duct sealing, commissioning, warranty, matched system).

### Why a lump-sum bid is useless for comparison

You cannot see what is included or left out.

### Rough fuel saving from AFUE 80 to 96

About 1 minus 80/96, roughly 17 percent of heating fuel (example math).

### 25C credit rate and heat pump cap on the IRS page

30 percent of qualified costs; $2,000 per year cap for qualified heat pumps.

### 25C cap for other items like efficient furnaces and ACs

Up to $600 per item (IRS 25C page).

### 25C placed-in-service window on the IRS page

On or after January 1, 2023 and before December 31, 2025.

### EPA refrigerant rule for new split systems after January 1, 2026

Must use a refrigerant with a GWP less than 700.

### Simple payback formula

Net cost divided by yearly saving, in years.

### Why compare ten-year cost, not just payback

Payback punishes replacing a machine that still works; ten-year cost shows the real total.

### What a permitted furnace replacement also triggers in a single-family house

The CO alarm requirement under C.R.S. 38-45-102.

## Quiz: 10 questions

Tap an answer. It shows right or wrong and opens the reason. Your score is saved in this browser and counts in the [study app](/courses/furnace-ac-heat-pumps/study).

- Which bid format lets you compare installers fairly?
**A** Lump-sum bid
- **B** Line-item bid
- **C** Verbal estimate
- **D** Whichever is lowest

### Show answer and why

**Answer: B.** Line-item bid

Only a line-item bid shows what each part costs and what is included.

Lesson definition

- On the IRS page, the 25C credit equals what share of qualified expenses?
**A** 10 percent
- **B** 20 percent
- **C** 50 percent
- **D** 30 percent

### Show answer and why

**Answer: D.** 30 percent

The IRS page states the credit equals 30% of certain qualified expenses.

IRS: Energy Efficient Home Improvement Credit (section 25C)

- The yearly 25C cap for qualified heat pumps on the IRS page is:
**A** $2,000
- **B** $600
- **C** $1,200
- **D** $5,000

### Show answer and why

**Answer: A.** $2,000

The page lists $2,000 per year for qualified heat pumps, water heaters, biomass stoves or boilers.

IRS: Energy Efficient Home Improvement Credit (section 25C)

- For other qualified items such as efficient furnaces and central ACs, the IRS page caps the credit at:
**A** $2,000 per item
- **B** $150 per item
- **C** $600 per item
- **D** No cap

### Show answer and why

**Answer: C.** $600 per item

The page says these items qualify for a credit up to $600 per item.

IRS: Energy Efficient Home Improvement Credit (section 25C)

- According to the IRS page, 25C applies to property placed in service:
**A** Any year after 2010
- **B** Only in 2026
- **C** Before January 1, 2023
- **D** On or after January 1, 2023 and before December 31, 2025

### Show answer and why

**Answer: D.** On or after January 1, 2023 and before December 31, 2025

The page gives that placed-in-service window.

IRS: Energy Efficient Home Improvement Credit (section 25C)

- The EPA page says a new split system installed after January 1, 2026 must use refrigerant with a GWP:
**A** Over 2,000
- **B** Less than 700
- **C** Exactly 410
- **D** Any value

### Show answer and why

**Answer: B.** Less than 700

The EPA page states the under-700 GWP limit for new split systems after that date.

EPA HFC phasedown FAQ

- Simple payback is:
**A** Net cost divided by yearly saving
- **B** Yearly saving divided by net cost
- **C** Install price times ten
- **D** Energy bill minus rebate

### Show answer and why

**Answer: A.** Net cost divided by yearly saving

Simple payback is net cost divided by yearly saving, giving years.

Lesson definition

- Static pressure in a duct system refers to:
**A** The gas pressure at the burner
- **B** The refrigerant pressure in the coil
- **C** The resistance the blower pushes against in the ducts
- **D** The weight of the outdoor unit

### Show answer and why

**Answer: C.** The resistance the blower pushes against in the ducts

Static pressure is duct resistance; too high hurts efficiency and equipment life.

Lesson definition

- In the example table, which option had the lowest ten-year cost?
**A** Keep repairing
- **B** Furnace only, 96 AFUE
- **C** Furnace plus AC
- **D** Dual-fuel heat pump

### Show answer and why

**Answer: B.** Furnace only, 96 AFUE

The furnace-only option's example ten-year cost was $20,900, the lowest, but it leaves the R-22 AC in place.

Worked example with made-up numbers

- A permitted fuel-fired appliance replacement in a single-family house triggers which requirement?
**A** A new roof inspection
- **B** A radon test
- **C** A seller disclosure of past repairs
- **D** An operational CO alarm under C.R.S. 38-45-102

### Show answer and why

**Answer: D.** An operational CO alarm under C.R.S. 38-45-102

The statute applies to permitted fuel-fired appliance replacements.

C.R.S. 38-45-102

[← Carbon monoxide, venting and the safety checks a buyer should ask for](/courses/furnace-ac-heat-pumps/hvac-06-carbon-monoxide-venting-and-the-safety-checks-a-buyer-should)

## After you study

[House with a dying furnace you'd rather not fix? Get a no-pressure as-is cash offer](/offer)

[Want houses whose systems are priced in? Make a free account and see Colorado's off-market seller lists](/join)

---
Agent index: [https://shinnslist.com/llms.txt](https://shinnslist.com/llms.txt)